Profile Information
Panel Type: Standing Seam
Panel Seam: SnapLock
Panel Width: 16”
Seam Height: 1.5”
Panel Material: 22 ga—24 ga min.
Panel Surface: Smooth / Embossed Optional
Panel Clip: Required Per Engineering
Minimum Slope: 3/12
Substrate: Plywood
Details
Description
Snaplock, clip-anchored panel with a 16” maximum panel width and a nominal rib height of 1.5”
Fastener
#10 1-inch pancake style fastener and nominally 3” long x 1.3” tall 24ga clip with (2) fasteners per clip.
Compliant with FBC 1506.6 where required.
Slope
Comply with local building code or FBC 1507.4.2 where required. FBC 1507.4.2 minimum slope is 1/4:12.
Re-Roofing
This panel may be installed over a single layer of existing shingles as permitted by local building
code or FBC 1511, provided the existing roof meets the conditions required by the applicable code.
Maximum Allowable Loads & Installation Requirements
Material | Method | Fastener Pattern | Clip Spacing | Allowable Pressure |
Steel | Method A | (2) #10 x 1” fasteners per clip | 12” o.c. | -86 PSF |
*A factor of safety of 2 has been applied.