Profile Information
Panel Type: Standing Seam
Panel Seam: SnapLock
Panel Width: 19” (Steel) / 15” (Aluminum)
Seam Height: 1.5”
Panel Material: 22 ga—24 ga min, .032–.040
Panel Surface: Smooth / Embossed Optional
Panel Clip: Required Per Engineering
Minimum Slope: 2/12
Substrate: Plywood (Steel), Plywood, B-Deck, B-Deck w/ISO (Aluminum)
Details
Description
Snaplock, clip-anchored panel with a 15.5” or 19” maximum panel width and a nominal rib height of 1.5”.
Fastener
#10 1-inch pancake style fastener and nominally 3.5” long x 1.5” tall 20ga clip with (2) fasteners per clip. Compliant with FBC 1506.6 where required.
Slope
Comply with local building code or FBC 1507.4.2/FBC 1515.2 where required. Outside the HVHZ, FBC 1507.4.2 minimum slope is 1/4:12. In the HVHZ, FBC 1515.2 minimum slope is 2:12.
Re-Roofing
This panel may be installed over a single layer of existing shingles as permitted by local building code or FBC 1511/1521, provided the existing roof meets the conditions required by the applicable code.
Maximum Allowable Loads & Installation Requirements
Material | Method | Fastener Pattern | Clip Spacing | Allowable Pressure |
Aluminum | Method A | (2) #10 x 1” fasteners per clip | 18” o.c. | -164.75 PSF |
Aluminum | Method B | (2) #10 x 1” fasteners per clip | 12” o.c. | -176 PSF |
Steel | Method A | (2) #10 x 1” fasteners per clip | 12” o.c. | -128.5 PSF |
*A factor of safety of 2 has been applied.